Page 1 - LGR DEHUMIDIFIER

Read these instructions before using the machine.86352290-J05/14/13Operating instructions (ENG)MODEL: 10079000LGR DEHUMIDIFIER

Page 2 - Warranty Registration

10SafetySafety Label LocationNOTE: These drawings indicate the location of safety labels on the Machine. If, at any time, the labels become illegible

Page 3 - Table of Contents

11OperationsTechnical SpecificationsSPECIAL NOTES:This appliance is not intended for use by persons (including children) with reduced physical, sensor

Page 4 - How To Use This Manual

12OperationsComponents1. Power Cord2. Handle3. Intake Nozzle/Cord Storage4. Filter5. Housing Lid6. Ducting Flanges7. Exhaust Nozzle8. Wheels9. Power S

Page 5 - IMPORTANT SAFETY INSTRUCTIONS

13OperationsHow to Transport Dehumidifier1. Wrap the power cord around intake nozzle.2. Tilt on back wheels with exhaust outlet pointing up. 3. Pull b

Page 6 - CONSERVEZ CES CONSIGNES

14Operating DehumidifierNever allow anything to block intake airflow. Be careful of objects which could be drawn against intake. The fan must sit on a

Page 7 - HAZARD INTENSITY LEVEL

15OperationsExhaust Ducting1. Place quick-ducting band over lay-flat duct approximately 1 foot from end.2. Slide ducting 3 or 4 inches over front

Page 8

16OperationsBack Draft PreventionExhausting too much air from a space with Open Combustion Devices (e.g. furnace, fireplace or water heater) can cause

Page 9

17MaintenanceService SchedulePower Cord Daily Inspect for wear, fraying or cuts.Filter Daily Inspect, vacuum up to 3 times, replace as neededCoils Mon

Page 10 - Safety Label Location

18MaintenanceFan ReplacementThe motorized impeller has internal thermal overload protection. If defective, the complete assembly must be replaced.1. U

Page 11 - SPECIAL NOTES:

19MaintenanceTroubleshootingPROBLEM CAUSE SOLUTIONNothing runsDefective switch Replace switch.Defective control board Replace control board.Loose conn

Page 12 - Components

2 86352290 Trident LGR DehumidifierMachine Data LabelOverviewThe Trident LGR Dehumidifier is intended for professional disaster restoration and remed

Page 13 - Cord Storage

20 86352290 Trident LGR DehumidifierNotes:

Page 14 - ATTENTION:

21PARTS86352290 Trident LGR DehumidifierParts

Page 15 - Intake Ducting

22Air Mover86352290 Trident LGR Dehumidifier12345678910

Page 16 - Purging Dehumidifier

2386352290 Trident LGR DehumidifierAir MoverREF PART NO. QTY DESCRIPTIONSERIAL NO. FROM NOTES1 86349360 8 SCR, PHMS M6 X 25 SS2 86341580 5 SPACER, D

Page 17 - Replace Condensate Pump

24Compressor134562786352290 Trident LGR Dehumidifier

Page 18 - Thermistor Replacement

2586352290 Trident LGR DehumidifierCompressorREF PART NO. QTY DESCRIPTIONSERIAL NO. FROM NOTES1 86350050 1 DISCHARGE TUBE2 86172650 3 NUT, M6, LK, I

Page 19 - Troubleshooting

26Electronics86352290 Trident LGR Dehumidifier2612345678910111213141516171819202122222122242325

Page 20

2786352290 Trident LGR DehumidifierElectronics* SEE SERIAL NUMBER PAGE** CALL MANUFACTURER FOR SERIAL NUMBERREF PART NO. QTY DESCRIPTIONSERIAL NO.

Page 21

28Frame & Wheels86352290 Trident LGR Dehumidifier1356789101113141516172161241715

Page 22 - Air Mover

2986352290 Trident LGR DehumidifierFrame & WheelsREF PART NO. QTY DESCRIPTIONSERIAL NO. FROM NOTES1 86341010 2 BRKT, ATTACHMENT2 86001660 2 HUBC

Page 23

3Table of ContentsMachine Data Label. . . . . . . . . . . . . . . . . . . . . . . . . .2Overview. . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 24 - Compressor

30Housing86352290 Trident LGR Dehumidifier1234567891025111211112121313

Page 25

3186352290 Trident LGR DehumidifierHousingREF PART NO. QTY DESCRIPTIONSERIAL NO. FROM NOTES1 86349360 4 SCR, PHMS M6 X 25 SS2 86013850 16 WASHER, M6

Page 26 - Electronics

32Housing-Upper12345678910111213141581216291186352290 Trident LGR Dehumidifier

Page 27

3386352290 Trident LGR DehumidifierHousing-UpperREF PART NO. QTY DESCRIPTIONSERIAL NO. FROM NOTES1 86349400 8 SCR, M4 X 20 FHMS SS2 86349360 5 SCR,

Page 28 - Frame & Wheels

34Condensate Pump91151234101010777888686352290 Trident LGR Dehumidifier

Page 29

3586352290 Trident LGR DehumidifierCondensate PumpREF PART NO. QTY DESCRIPTIONSERIAL NO. FROM NOTES1 86351420 1 FITTING, QUICK DISCONNECT2 86341910

Page 30

36Refrigeration13161414121316141261234578910111213141516171486352290 Trident LGR Dehumidifier

Page 31 - NO. FROM

3786352290 Trident LGR DehumidifierRefrigerationREF PART NO. QTY DESCRIPTIONSERIAL NO. FROM NOTES1 86349390 1 THERMISTOR ASSY2 86349270 1 FAN SHROUD

Page 32 - Housing-Upper

38Wiring Diagram-C2TP8TP7+K1-S2-S1-SENSORbn/4bn/4sw/1sw/9sw/10bl/11 bl/12+Fge/15bl/7bn/8-X21 5 6 3 24-X13 1 4 2bn/14 rt/6 bl/5 ge/13ws/18bl/21vi/17bl/

Page 33

3986352290 Trident LGR DehumidifierWiring DiagramREF PART NO. QTY DESCRIPTIONSERIAL NO. FROMNOTES- 86337830 1 HARNESS, DEHU 110 PINT- 86351670 1 HARN

Page 34 - Condensate Pump

4How To Use This ManualThis manual contains the following sections:• How to Use This Manual•Safety• Operations• Maintenance•Parts ListThe HOW TO USE T

Page 35

40Suggested Spare PartsPART NO. DESCRIPTIONSERIAL NO. FROMNOTES86349620 CORD ASSY, 14/3 SJT X 30' BLK86343660 CAPACITOR, 45 µF86341930 CAPACITOR,

Page 36 - Refrigeration

41Serial NumbersREF. NO.MODEL: SERIAL #1 1007900000047186352290 Trident LGR Dehumidifier

Page 37

5SafetyIMPORTANT SAFETY INSTRUCTIONSWhen using this machine, basic precautionmust always be followed, including the following:READ ALL INSTRUCTIONS BE

Page 38 - Wiring Diagram

6SafetyCONSIGNES IMPORTANTES DE SÉCURITÉLors de l'utilisation d'un appareil électrique, il faut toujours observer des précautions élémentair

Page 39

7SafetyThe following symbols are used throughout this guide as indicated in their descriptions: HAZARD INTENSITY LEVELThere are three levels of hazard

Page 40 - Suggested Spare Parts

8SafetyLes symboles ci-dessous sont utilisés à travers ce manuel comme illustré dans leurs descriptions: DEGRÉS DE RISQUES EN CAS DE DANGERIl existe t

Page 41 - Serial Numbers

9Safety115V Grounding Instructions ELECTRICAL:In the USA this machine operates on a standard 15 amp 115V, 60 hz, A.C. power circuit. The amp, hertz